Albany UltraSmart Service Manual

Browse online or download Service Manual for Garage Door Opener Albany UltraSmart. Albany UltraSmart Technical data User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
UltraSecure 3000 with UltraSmart Owners Manual
Doors are UltraRugged, UltraReliable, UltraAffordable.
Albany Door Systems - A Company of Albany International Corp. All Rights Reserved
1080 Maritime Drive, Port Washington, WI 53074 - 975-A Old Norcross Road, Lawrenceville, Georgia 30046
262-268-9885 www.albanydoors.com
PN: 001451
Rev. 9/27/2010
Version 4.20
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - Version 4.20

UltraSecure 3000 with UltraSmart Owners Manual Doors are UltraRugged, UltraReliable, UltraAffordable. Albany Door Systems - A Company of Albany Int

Page 2 - STATEMENT OF WARRANTY

9 Manual #001451 Version 4.2 Before checking the following mentioned components the cover in front of the spring housing and eventually the existin

Page 3 - TABLE OF CONTENTS

Rev. 9/27/2009 Manual #001451 10 Operation High Speed Doors Safety Instructions Area of Application and Classified Use Unless explicitly described

Page 4 - INTRODUCTION

11 Manual #001451 Version 4.2 General Safety Advice Please read the user manual carefully and keep it easily accessible for future use. Always foll

Page 5 - Product Description

Rev. 9/27/2009 Manual #001451 12 Operation High Speed Doors Troubleshooting To avoid damage to the door or injury to personnel during repair of m

Page 6

13 Manual #001451 Version 4.2 Electrical Malfunctions For repair of electrical malfunctions see the error code manual at the appendix of the user m

Page 7 - Technical Data

Rev. 9/27/2009 Manual #001451 14 Operation High Speed Doors Inspection and Maintenance Maintenance and inspection work must only be per-formed by

Page 8

15 Manual #001451 Version 4.2 Controls Figure 1 Control Panel Key This key pad opens the door and stops the delay timer from closing the door. This

Page 9

Rev. 9/27/2009 Manual #001451 16 Operation High Speed Doors Control Panel Display The display on the front of the control panel shows two lines of

Page 10 - Inspection Plan

17 Manual #001451 Version 4.2 Line One (1) Text Line Two (2) Text Startup: R-Bac Industries Door Not Ready Normal Operation: Door ready Open

Page 11 - Safety Instructions

Rev. 9/27/2009 Manual #001451 18 Operation High Speed Doors Adjustments Door Limit Adjustments Door limit adjustments are used to set four height

Page 12 - Additional Advise

1 Manual #001451 Version 4.2 STATEMENT OF WARRANTY UltraSecure 3000 High Speed Doors ONE-YEAR WARRANTY ON MECHANICAL AND ELECTRICAL COMPONENTS Alb

Page 13 - Troubleshooting

19 Manual #001451 Version 4.2 Periodic Maintenance Continued… Quarterly Inspection 1. Perform daily inspection. 2. Check all mounting hardware an

Page 14 - Maintenance

Rev. 9/27/2009 Manual #001451 20 Operation High Speed Doors Trouble Shooting Continued... DISPLAY OR DOOR Problem Possible Cause Corrective Actio

Page 15

21 Manual #001451 Version 4.2 Trouble Shooting Continued... Light Curtain Problem Possible Cause Corrective Action Red alarm LED on. Transmitter

Page 16 - UltraSmart Control Panel

Rev. 9/27/2009 Manual #001451 22 Operation High Speed Doors Trouble Shooting Continued... Motor Drive Fault Problem Possible Cause Corrective Act

Page 17 - Operator Service

23 Manual #001451 Version 4.2 MOTOR WIRING 6"¼”MOTOR WIRESDRILL ONLY INTO BOTTOM OF BOXUSE MINIMUM ¾” CONDUIT¾”MOTOR WIRE CONDUITSEPARATEFOIL

Page 18

Rev. 9/27/2009 Manual #001451 24 Operation High Speed Doors ACTIVATION WIRING HMANUALACTIVATORS13456MODULE - ACONNECT AS “NORMALLY OPEN”2TB2REMOTE

Page 19 - Adjustments

25 Manual #001451 Version 4.2

Page 20

Rev. 9/27/2009 Manual #001451 26 Operation High Speed Doors

Page 21

27 Manual #001451 Version 4.2

Page 22

Rev. 9/27/2009 Manual #001451 28 Operation High Speed Doors

Page 23

Rev. 9/27/2009 Manual #001451 2 Operation High Speed Doors TABLE OF CONTENTS ALBANY DOOR SYSTEMS CONTACT INFORMATION: Port Washington, WI 1080 M

Page 24 - ENCODER WIRING

29 Manual #001451 Version 4.2 ENABLING THE WIRELESS SAFETY SYSTEM If the door is equipped with Albany’s Wireless Safety System (indicated by the la

Page 25

Rev. 9/27/2009 Manual #001451 30 Operation High Speed Doors UltraSmart™ STARTUP PROCEDURE Albany’s UltraSmart™ control system is designed to accomm

Page 26

31 Manual #001451 Version 4.2 SETTING SYSTEM OPTIONS 1) Press and hold until ―LIMIT SETUP‖ is shown on the display; Press 2) Press until

Page 27 - High Speed Doors

Rev. 9/27/2009 Manual #001451 32 Operation High Speed Doors Instructions for Using Over-Travel Brake System. About the Over-Travel Brake System Yo

Page 28

33 Manual #001451 Version 4.2 Resetting the Brake To reset the brake, first loosen the clamp screws (Fig 3) so that you can move the yoke up and do

Page 29

Rev. 9/27/2009 Manual #001451 34 Operation High Speed Doors Electrical Operation Instructions When the over-travel mechanism has been engaged, the

Page 30

35 Manual #001451 Version 4.2

Page 31 - SETUP

Rev. 9/27/2009 Manual #001451 36 Operation High Speed Doors

Page 32 - SETTING TIMERS

37 Manual #001451 Version 4.2

Page 33

Rev. 9/27/2009 Manual #001451 38 Operation High Speed Doors

Page 34 - Resetting the Brake

3 Manual #001451 Version 4.2 INTRODUCTION The contents of this manual are designed to help you operate and maintain Albany UltraLite™, UltraFast™,

Page 35

39 Manual #001451 Version 4.2

Page 36

Rev. 9/27/2009 Manual #001451 40 Operation High Speed Doors

Page 37

41 Manual #001451 Version 4.2

Page 38

Rev. 9/27/2009 Manual #001451 42 Operation High Speed Doors

Page 39

1080 Maritime Drive, Port Washington, WI 53074 Phone: (262) 268-9885 Fax: (262) 268-9895 albanydoors.com

Page 40

Rev. 9/27/2009 Manual #001451 4 Operation High Speed Doors Product Description Principle The UltraSecure 3000 is a vertically opening high-speed r

Page 41

5 Manual #001451 Version 4.2 Control Unit The UltraSecure 3000 is operated by a frequency converter control unit, which enables smooth ac-celeratio

Page 42

Rev. 9/27/2009 Manual #001451 6 Operation High Speed Doors Mechanical Safety Devices Springs are situated in separate chambers serving as a weight

Page 43

7 Manual #001451 Version 4.2 UltraSecure 3000 10’ high up to 16’ high

Page 44

Rev. 9/27/2009 Manual #001451 8 Operation High Speed Doors UltraSecure 3000 up to 10’ high